Comparison of XRF, TXRF, and ICP-MS Methods for Determination of Mercury in Face Creams
DOI:
https://doi.org/10.21423/JRS-V09I2VRDOLJAKKeywords:
mercury, face creams, XRF, TXRF, ICP-MSAbstract
Regulatory, media, and watchdog groups have identified numerous face cream products containing percent levels of mercury that far exceed the 1 ppm FDA regulatory limit. Mercury is added to these products to provide skin bleaching properties, and this poses a serious health risk to consumers. This study compares XRF, TXRF, and the more widely accepted ICP-MS methods for determination of mercury in face cream products. To identify contaminated products in a field setting, XRF is the preferred method, as it involves direct analysis of the sample, analysis times of a minute or less, and detection limits down to single ppm levels. XRF analysis gave quantitative results that compared well to those from ICP-MS for homogeneous products, but gave more variable results for products containing small crystals or chunks of inorganic mercury salts. More accurate results for these products requires preparation of a representative sample, microwave digestion, and TXRF or ICP-MS analysis. Given the continued production and distribution of mercury-containing face cream products, it is recommended that portable XRF be used to screen for such products or for accurate quantification of mercury in homogeneous products, and TXRF be used to determine the mercury content of more heterogeneous products.
References
Al-Saleh, I., Khogali, F., Al-Amodi, M., El-Doush, I., Shinwari, N., & Al-Baradei, R. (2003). Histopathological Effects of Mercury in Skin-Lightening Cream. Journal of Environmental Pathology, Toxicology and Oncology, 22(4), 287-299. https://www.doi.org/10.1615/JEnvPathToxOncol.v22.i4.30
Bennun, L., & Sanhueza, V. A. (2010). Procedure for the Improvement in the Determination of a TXRF Spectrometer Sensitivity Curve. Analytical Sciences, 26(3), 331-335. https://www.doi.org/10.2116/analsci.26.331
Borgese, L., Zacco, A., Bontempi, E., Pellegatta, M., Vigna, L., Patrini, L., Riboldi, L., Rubino, F. M., & Depero, L.E. (2010). Use of Total Reflection X-Ray Fluorescence (TXRF) for the Evaluation of Heavy Metal Poisoning due to the Improper Use of a Traditional Ayurvedic Drug. Journal of Pharmaceutical and Biomedical Analysis, 52(5), 787-790. https://www.doi.org/10.1016/j.jpba.2010.02.030
Borgese, L., Dalipi, R., Riboldi, A., Bilo, F., Zacco, A., Federici, S., Bettinelli, M., Bontempi, E., & Depero, L. E. (2017). Comprehensive approach to the validation of the standard method for total reflection X-ray fluorescence analysis of water. Talanta, 181, 165-171. https://www.doi.org/10.1016/j.talanta.2017.12.087
Centers for Disease Control and Prevention. (2012, January 20). Mercury Exposure Among Household Users and Nonusers of Skin-Lightening Creams Produced in Mexico -- California and Virginia, 2010. Morbidity and Mortality Weekly Report, 61(2), 33-36.
Chan, T. Y. K. (2011). Inorganic Mercury Poisoning Associated with Skin-Lightening Cosmetic Products. Clinical Toxicology, 49(10), 886-891. https://www.doi.org/10.3109/15563650.2011.626425
FDA Bans Skin Whitening Products due to Mercury Content. (2011, August 6). The Manila Paper.
Gabler, E. & Roe, S. (2010, May 18). Some Skin Whitening Creams contain Toxic Mercury, Testing Finds. Chicago Tribune.
Gabler, E. & Roe, S. (2010, May 25). Mercury Content of Skin-Lightening Creams. Chicago Tribune.
Geer, L. A., Persad, M. D., Palmer, C. D., Steuerwald, A. J., Dalloul, M., Abulafia, O., & Parsons, P. J. (2012). Assessment of Prenatal Mercury Exposure in a Predominately Caribbean Immigrant Community in Brooklyn, NY. Journal of Environmental Monitoring, 14(3), 1035-1043. https://www.doi.org/10.1039/C2EM10835F
International Organization for Standardization. (2015, July). Surface chemical analysis -- Use of Total Reflection X-ray Fluorescence spectroscopy in biological and environmental analysis. ISO/TS 18507:2015. Retrieved November 2020 from https://www.iso.org/standard/62700.html
International Organization for Standardization. (2018, March). Surface chemical analysis -- Total reflection X-ray fluorescence analysis of water. Retrieved November 2020 from https://www.iso.org/standard/67511.html
McKelvey, W., Jeffery, N., Clark, N., Kass, D., & Parsons, P. J. (2011). Population-Based Inorganic Mercury Biomonitoring and the Identification of Skin Care Products as a Source of Exposure in New York City. Environmental Health Perspectives, 119(2), 203-209. https://www.doi.org/10.1289/ehp.1002396
Murphy, T., Lim, S., Huong, S. P., Irvine, K., Bayen, S., Kelly, B. C., & Wilson, K. (2012). Application of Handheld X-Ray Fluorescence Analyzers to Identify Mercury in Skin-Whitening Creams in Cambodia. Blacksmith Institute Journal of Health Pollution, 2(3), 1-32.
Olumide, Y. M., Akinkugbe, A. O., Altraide, D., Mohammed, T., Ahamefule, N., Ayanlowo, S., Onyekonwu, C., & Essen, N. (2008). Complications of chronic use of skin lightening cosmetics. International Journal of Dermatology, 47(4), 344-353. https://www.doi.org/10.1111/j.1365-4632.2008.02719.x
Palmer, P. T., Jacobs, R., Baker, P. E., Ferguson, K., & Webber, S. (2009). Use of Field-Portable XRF Analyzers for Rapid Screening of Toxic Elements in FDA-Regulated Products. Journal of Agricultural and Food Chemistry, 57(7), 2605-2613. https://www.doi.org/10.1021/jf803285h
Palmer, P. T., Jacobs, R., Vrdoljak, G., Nausin, M., Qiu, C., & Yee, S. (2013, May). Use of Field Portable XRF for Screening and Quantitation of Mercury in Face Creams. FDA Laboratory Information Bulletin # 4542, 1-10.
Peregrino, C. P., Moreno, M. V., Miranda, S. V., Rubio, A. D., & Leal, L. O. (2011). Mercury Levels in Locally Manufactured Mexican Skin-Lightening Creams. International Journal of Environmental Research and Public Health, 8(6), 2516-2523. https://www.doi.org/10.3390/ijerph8062516
U.S. Food and Drug Administration. (2019). Requirements for Specific Cosmetic Products, 21 CFR § 700.13 Retrieved November 2020 from https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfCFR/CFRSearch.cfm?fr=700.13&SearchTerm=mercury
Wencong, W. & Xin, Z. (2012, April 11). Whitening Creams Packed with Excessive Metals. China Daily.
Downloads
Published
Versions
- 2021-02-14 (2)
- 2021-02-14 (1)
Issue
Section
License
Copyright (c) 2021 Gordon Vrdoljak, Peter Palmer, Richard Jacobs, Bahman Moezzi, Alanna Viegas
This work is licensed under a Creative Commons Attribution 4.0 International License.
By submitting content to the Journal of Regulatory Science (JRS), authors agree to the following terms:
- Authors retain copyright and grant the JRS the right of first publication. Authors retain patent, trademark, and other intellectual property rights (including research data) and grant third parties the right to use, reproduce, and share the article according to the Creative Commons — Attribution-NonCommercial 4.0 International — CC BY-NC 4.0 license agreement. The JRS is an open access journal and, as a result, articles are free to use with proper acknowledgment of the work's authorship and initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process.
- If excerpts from other copyrighted works are included, the author(s) must obtain written permission from the copyright owners and credit the source(s) in the article.
- The publication of the submission has been approved by all co-authors and responsible authorities at the institute or organization where the work has been carried out.
- Copyright has not been breached in seeking publication of the submission.